Fiber glass composite laminates (FGCL) measurement using 3 axis pulse echo scanning unit

Mahmod, M.F. and Bakar, E.A. and Othman, A.R. and Ramzi, A.R. and Goh, C.Y. (2015) Fiber glass composite laminates (FGCL) measurement using 3 axis pulse echo scanning unit. Jurnal Teknologi, 76 (1). pp. 147-155.

Full text not available from this repository.
Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Ultrasonic is a common non-destructive testing for composite laminates inspection. However, high cost caused limited budget organization to own this equipment for their research activities. Our work seeks to develop an automated and reliable ultrasonic scanning unit with affordable cost. The validation of scanning speed using Arduino UNO Microcontroller has successfully achieved by determined the stepping mode. This prototype is suggested to inspect surface defect on glass fiber composite laminates up to 6 mm in thickness as the probe limitation for optimum scanning performance. The optimum scanning speed for this prototype was 12 mm/sec using micro step setup while the average percentage of different against ten times inspection are as low as five percent. © 2015 Penerbit UTM Press. All rights reserved.

Item Type: Article
Impact Factor: cited By 3
Depositing User: Ms Sharifah Fahimah Saiyed Yeop
Date Deposited: 26 Mar 2022 03:22
Last Modified: 26 Mar 2022 03:22
URI: http://scholars.utp.edu.my/id/eprint/31542