Failure analysis of connecting rod

Andoko, A. and Nauri, I.M. and Paryono, P. and Kurniawan, P. and Pradica, D.R. and Jeadi, R.P. and Prasetya, R. and Ginta, T.L. (2020) Failure analysis of connecting rod. In: UNSPECIFIED.

Full text not available from this repository.
Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Increasing the volume of combustible motor vehicles, needs to be anticipated as early as possible if there is a failure on the combustion engine components. Failure that may occur on the component is the connecting rod. This study aims to determine the cause of the failure of a connecting rod car. The method used in this study consisted of several tests namely, macro photographs, microstructure test, SEM/EDX and hardness test. The results show that the specimen is AISI 4315 with a hardness of 30.98 RC. The specimen has a hard surface but is resilient on the inside. This can be seen from the shape of the fault that has a lot of dimple, beachmark, and fracture folds. © 2020 American Institute of Physics Inc.. All rights reserved.

Item Type: Conference or Workshop Item (UNSPECIFIED)
Impact Factor: cited By 0
Depositing User: Ms Sharifah Fahimah Saiyed Yeop
Date Deposited: 25 Mar 2022 03:17
Last Modified: 25 Mar 2022 03:17
URI: http://scholars.utp.edu.my/id/eprint/29983