Mohammed, B.S. and Aswin, M. and Liew, M.S. and Zawawi, N.A.W.A. (2019) Structural Performance of RC and R-ECC Dapped-End Beams Based on the Role of Hanger or Diagonal Reinforcements Combined by ECC. International Journal of Concrete Structures and Materials, 13 (1).
Full text not available from this repository.Abstract
Twenty-seven large-scale beams with dapped-end have been prepared, cast and tested to failure in the three points loading arrangement. One control beam has been designed in accordance with requirement of standard code while the dapped-end reinforcement scheme of other beams has been derived from the control beam. In selected beams, engineered cementitious composites (ECC) has been utilized in the dapped-end region. The test results exhibited that DR is more appropriate and higher capacity than HR in resisting the shear force. In addition, the reinforced engineered cementitious composites dapped-end beams (R-ECC-DEB) showed higher structural performance compared to the normal reinforced concrete dapped-end beams (RC-DEBs). The strength of ECC also has direct effect on the failure capacity of the R-ECC-DEB, in which higher strength of ECC leads to higher failure capacity of R-ECC-DEB. © 2019, The Author(s).
Item Type: | Article |
---|---|
Impact Factor: | cited By 8 |
Uncontrolled Keywords: | Failure modes; Materials, Control beams; Crack patterns; Dapped-end beams; Engineered cementitious composite (ECC); Failure load; Resisting the shears; Standard codes; Structural performance, Reinforced concrete |
Depositing User: | PROF IR DR MOHD SHAHIR LIEW |
Date Deposited: | 27 Aug 2021 08:42 |
Last Modified: | 03 Feb 2023 13:24 |
URI: | http://scholars.utp.edu.my/id/eprint/24854 |