Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies

Mutafi, M.A. and Nasif, M.S. and Pao, W. and Ismail, F.B. (2017) Numerical investigation on the effect of balcony open and solid upstand on smoke contamination in atrium balconies. Journal of Physics: Conference Series, 908 (1).

Full text not available from this repository.
Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Atrium is a modern architectural design of buildings that has an open space at the middle and contains several floors. In atrium structure the smoke due to fire can easily flow through the open spaces and causes smoke contamination. CFD simulation using fire dynamic simulator (FDS) software is conducted in this work, to investigate the effect of balcony open upstand on smoke contamination in atrium's balconies and compare it with balconies with solid upstand. It was found that in case of open upstand, the smoke contamination occurrence decreased inside the balcony comparing with balconies with solid upstand. © 2017 Published under licence by IOP Publishing Ltd.

Item Type: Article
Impact Factor: cited By 0
Departments / MOR / COE: Division > Academic > Faculty of Engineering > Mechanical Engineering
Depositing User: Mr Ahmad Suhairi Mohamed Lazim
Date Deposited: 22 Apr 2018 13:47
Last Modified: 22 Apr 2018 13:47
URI: http://scholars.utp.edu.my/id/eprint/19940

Actions (login required)

View Item
View Item