The Influence of Cable Capacitance, Generator Neutral Grounding and Zig-zag Transformer to Third Harmonic Produced by Synchronous Generator

Abdullah, M. F. and Hamid, Nor Hisham and Baharudin , Z. and Razak , M. H. S. A. and Hisham , M. I. B. (2012) The Influence of Cable Capacitance, Generator Neutral Grounding and Zig-zag Transformer to Third Harmonic Produced by Synchronous Generator. In: The 10th International Power & Energy Conference, IPEC 2012, 12 – 13 December 2012, Ho Chi Minh City, Vietnam.

[thumbnail of IPEC 2012 The Influence of Cable Capacitance, Generator Neutral Grounding and Zig-zag Transformer to Third Harmonic Produced by Synchronous Generator.pdf]
Preview
PDF
IPEC 2012 The Influence of Cable Capacitance, Generator Neutral Grounding and Zig-zag Transformer to Third Harmonic Produced by Synchronous Generator.pdf

Download (136kB) | Preview

Abstract

Salient pole synchronous generator is one of harmonic sources that causes various power system harmonic problem especially related to neutral. This paper aims to study the characteristics of third harmonic voltage and current from generator when connected to balanced load via cable, generator load connection with different generator neutral grounding resistor and generator load connection shunted by zig-zag transformer. Lab scale experiments have been conducted to study the variation of all parameters related to cable capacitor and generator neutral grounding resistor under various combined resistive and inductive load. Cable capacitance which depends on cable length, size and number of parallel cable, combined with load impedance determines the third harmonic current magnitude. The presence of cable capacitance that interact with generator inductance resulted to series harmonic resonance at 9th and 15th harmonic order that causes high 9th and 15th harmonic current flowing between generator and cable capacitor. Generator neutral grounding resistor can effectively reduce the third harmonic in the phase and neutral. Very high generator neutral grounding resistor should not be used since it can also restrict earth fault current that may pose problem to the sensitivity of earth fault protection system. Zig-zag transformer efficiently divert third harmonic current from generator to enter the load but high circulating third harmonic current between generator and zig-zag transformer may pose heating problem to the equipments.

Item Type: Conference or Workshop Item (Paper)
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Departments / MOR / COE: Departments > Electrical & Electronic Engineering
Research Institutes > Energy
Depositing User: Ir Mohd Faris Abdullah
Date Deposited: 16 Dec 2013 23:48
Last Modified: 16 Dec 2013 23:48
URI: http://scholars.utp.edu.my/id/eprint/10562

Actions (login required)

View Item
View Item