Facile synthesis of MoS2 nanoflower-Ag NPs grown on lignin-derived graphene for Troponin I aptasensing

Vasudevan, M. and Remesh, S. and Perumal, V. and Raja, P.B. and Ibrahim, M.N.M. and Gopinath, S.C.B. and Karuppanan, S. and Ovinis, M. (2023) Facile synthesis of MoS2 nanoflower-Ag NPs grown on lignin-derived graphene for Troponin I aptasensing. Chemical Engineering Journal, 468. ISSN 13858947

Full text not available from this repository.
Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

This article presents the development and application of a green lignin-derived graphene biosensor for Troponin I, a biomarker for Acute Myocardial Infarction (AMI). The graphene was synthesized from oil palm lignin through an optimized laser scribing process. While the three-dimensional nature of the laser-scribed lignin-derived graphene (3D LSG) is advantageous, it suffers from poor electrical conductivity due to the amorphous nature of lignin. Therefore, semi-conductive molybdenum disulphide (MoS2) precursor with conductive green silver nanoparticles (Ag NPs) was added to 0.5, 1.0, 1.5, and 2.0 g of 3D LSG to synthesize 3D LSGMoS2Ag NPs hybrids via an aqueous hydrothermal process. Morphological, physical, and structural analyses showed the presence of petal-like MoS2 nanoflower with Ag NPs on the 3D LSG surface. The strong interrelation between 3D LSG, MoS2, and Ag NPs was confirmed by X-ray spectroscopy, Raman spectroscopy and energy dispersive spectroscopy (EDS). Specifically, X-ray spectroscopy revealed the formation of O1s, Ag 3d, C1s, Mo 3d, and S2p in the 3D LSGMoS2Ag NPs-2.0 hybrid. Raman spectroscopy revealed an enhancement in the surface area of the 3D LSGMoS2Ag NPs-2.0 hybrid, which enhances the detection sensitivity. The 3D LSGMoS2Ag NPs hybrid was subsequently chemically modified and immobilised with an aptamer to interact with Troponin I on an impedimetric sensor. The 3D LSGMoS2Ag NPs hybrid showed high analytical performance, high specificity, and a � 4-fold increment in selectivity, with a detection limit of 100 attomolar. This biosensor has a sensitivity of 31.45 µA mM�1 cm�2, stability of 87, with a relative standard deviation for reproducibility of 3.8. © 2023

Item Type: Article
Impact Factor: cited By 1
Uncontrolled Keywords: Biomarkers; Cardiology; Energy dispersive spectroscopy; Graphene; Layered semiconductors; Lignin; Molybdenum disulfide; Palm oil; Raman spectroscopy; Silver nanoparticles, Acute myocardial infarction; Development and applications; Electrical conductivity; Facile synthesis; Laser scribed graphene; Laser scribing process; Oil palm; Synthesised; Troponin; X-ray spectroscopy, Biopolymers, Area; Detection; Oil; Processes; Raman Spectroscopy; Sensitivity; Stability
Depositing User: Mr Ahmad Suhairi Mohamed Lazim
Date Deposited: 04 Oct 2023 13:19
Last Modified: 04 Oct 2023 13:19
URI: http://scholars.utp.edu.my/id/eprint/37482

Actions (login required)

View Item
View Item